CHECK VALVE (TWO-WAY) INSPECTION [MZR 2.0 DISI i-stop]
id0116a9093700
Integrated rollover valve
-
Note
-
• The check valve (two-way) cannot be disassembled and inspected as it is built into the rollover valve.
1. Perform the fuel tank inspection. (See FUEL TANK INSPECTION [MZR 2.0 DISI i-stop].)
-
Integrated evaporative hose
-
Note
-
• The check valve (two-way) cannot be removed as a single unit. When replacing the check valve (two-way), replace it together with the evaporative hose as a single unit.
1. Remove the evaporative hose with the check valve (two-way). (See FUEL TANK REMOVAL/INSTALLATION [MZR 2.0 DISI i-stop].)
2. Apply pressure port A and verify that there is airflow.
-
• If there is no airflow, replace the evaporative hose with the check valve (two-way).
3. Apply negative pressure to port A and verify that there is airflow with a vacuum of 0.9 kPa or more.
-
• Replace the evaporative hose with the check valve (two-way) in the following cases:
-
― There is no airflow with vacuum of 0.9 kPa or more
― There is airflow with vacuum of less than 0.9 kPa