A/C CUT-OFF CONTROL OPERATION [L3 Turbo]


id0140b6103700

•  The PCM stops energization to the A/C relay when any of the following conditions are met:

A/C cut-off control operation conditions

Operation condition

A/C relay non-energization period

Purpose

At engine start
Approx. 4 s
Improved startability
Accelerator opening angle 50 % or more
Approx. 3 s
Improved drive-away performance
During acceleration (accelerator opening angle 25 % or more)
Approx. 3 s
Improved acceleration performance
When the engine coolant temperature is 113 °C {235 °F} or more
Repeatedly turns on and off every 10 s until the engine coolant temperature is less than approx. 108 °C {226 °F}
Improved engine reliability
When the engine coolant temperature is 118 °C {244 °F} or more
Until the engine coolant temperature decreases to less than approx. 110 °C {230 °F}
Improved engine reliability
At high engine speed (engine speed 6,300 rpm or more)
Until engine speed decreases to less than 5,800 rpm
Improved engine speed stability