AIR BYPASS VALVE POSITION SENSOR CONSTRUCTION/OPERATION [MZ-CD 1.6 (Y6) (EURO4 emission level)]


id0140j5182100

•  Detects the fluctuation in voltage (variable resistance) of the air bypass valve opening angle and inputs it to the PCM. The voltage input to the PCM increases proportionately to the increase in air bypass valve opening angle.
•  Installed as connected to the valve shaft so that it corresponds to the opening and closing of the air bypass valve.
am3zzn00002705