ON-BOARD DIAGNOSTIC SYSTEM PID/DATA MONITOR FUNCTION [FN4A-EL]


id050218280600


Function

•  The PID mode allows access to certain data values, analog and digital input and output, calculations and system state information.

PID/DATA Monitor Table

Note
•  Only the transaxle-related information is described.

Item

Definition

Unit/Condition

DWN SW
Down switch condition
On/Off
GEAR
Gear commanded by module
1st/2nd/3rd/4th
HTM_CNT
Number of high oil temperature mode (ATF temperature at 130 °C {266 °F} or more) operations
HTM_DIS
Travel distance after operation of high oil temperature mode (ATF temperature at 130 °C {266 °F} or more)
km {mile}
LINEDES
Target line pressure
Pa
LPS
Pressure control solenoid control signal in PCM
A
MNL SW
M range switch condition
On/Off
OSS
Output shaft speed
RPM
SSA/SS1
Shift solenoid A control signal in PCM
%
SSB/SS2
Shift solenoid B control signal in PCM
%
SSC/SS3
Shift solenoid C control signal in PCM
%
SSD/SS4
Shift solenoid D control signal in PCM
On/Off
SSE_SS5
Shift solenoid E control signal in PCM
On/Off
TFT
ATF temperature
°C {°F}
TFTV
Input voltage from TFT sensor
V
TR
Transaxle range
P/R/N/D
TR_SENS
Input voltage from TR switch
V
TSS
Input shaft speed
RPM
UP SW
Up switch condition
On/Off