ON-BOARD DIAGNOSTIC SYSTEM SIMULATION FUNCTION [FS5A-EL]


id050221280700


Function

•  By using the scan tool, simulation items for output parts preset in the TCM can be optionally selected and operated regardless of TCM control conditions.

Simulation Table

Item

Definition

Unit/Condition

Operating condition

LPS
Pressure control solenoid A
A
Idling (P or N position)
LPSB
Pressure control solenoid B
%
Idling (P or N position)
SSA/SS1
Shift solenoid A
%
Idling (P or N position)
SSB/SS2
Shift solenoid B
%
Idling (P or N position)
SSC/SS3
Shift solenoid C
%
Idling (P or N position)
SSD/SS4
Shift solenoid D
On/Off
Idling (P or N position)
SSE_SS5
Shift solenoid E
On/Off
Idling (P or N position)
SSF_SS6
Shift solenoid F
On/Off
Idling (P or N position)