PRIMARY PULLEY SPEED SENSOR REMOVAL/INSTALLATION [DJVA-EL]
id051901286700
1. Remove the primary pulley speed sensor.
- (1) Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [ZY, Z6].)
- (2) Disconnect the negative battery cable.
- (3) Disconnect the primary pulley speed sensor connector.
- (4) Remove the primary pulley speed sensor.
- (5) Remove the O-ring
-
2. Install in the primary pulley speed sensor.
- (1) Coat a new O-ring with CVT fluid, and install it to the pulley speed sensor.
- (2) After verifying the sensor condition, install the primary pulley speed sensor using a new bolt.
-
-
Tightening torque
-
3.9—6.9 N·m {40—70 kgf·cm, 35—61 in·lbf}
3. Connect the primary pulley speed sensor connector.
4. Connect the negative battery cable.
5. Install the battery cover. (See BATTERY REMOVAL/INSTALLATION [ZY, Z6].)