SAS CONTROL MODULE FUNCTION [TYPE B]
id0810001010k5
-
Note
-
• The SAS control module type differs depending on whether the DSC combined sensor is integrated.
-
― Type A: Separate combined sensor (3 module connectors)
― Type B: Built-in combined sensor (2 module connectors)
Sensing Function
• The following sensors are built into the SAS control module.
-
― Crash sensor
― Yaw rate sensor
― Low-G (XY) sensor
Crash Sensor
• If the degree of impact detected by the crash zone sensor and the crash sensor built into the SAS control module exceeds the set value during a frontal collision to the vehicle, the SAS control module sends an operation (deployment) signal to the air bag module and the pre-tensioner seat belts.
• If the degree of impact detected by side air bag sensor No. 1 or No. 2 and the crash sensor built into the SAS control module exceeds the set value during a side collision to the vehicle, the SAS control module sends an operation (deployment) signal to the side air bag module and curtain air bag module.
Yaw Rate Sensor
• The yaw rate sensor in the SAS control module detects the vehicle yaw rate (vehicle turning angle speed), and sends the detected rate to the DSC HU/CM via special CAN lines between the SAS control module and the DSC HU/CM.
Low-G (XY) sensor
• The low-G (XY) sensor in the SAS control module detects the vehicle longitudinal accelerations, and sends the detected accelerations to the DSC HU/CM via special CAN lines between the SAS control module and the DSC HU/CM.
Backup Power Supply Function
• The backup power supply function enables the condenser to discharge and supply power to assure air bag system operation/deployment properly for a specified time even if the power supply to the SAS control module is cut due to a collision.
Configuration Function
• Identifies the variation of the air bag module installed to the vehicle when replacing the SAS control module with a new one.
• If the air bag module installed to the vehicle and the module identified by the SAS control module differ, a DTC is displayed.
• Refer to the Workshop Manual for the configuration setting procedure.