DTC P0850:29 [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM]


id09021c406400

DESCRIPTION

Erratic signal of TR switch

DETECTION CONDITION
•  CAN and TR switch signals do not correspond while the ignition switch is ON.
―  Keyless control module detects that the TR switch stuck off.
•  Starter monitor input voltage is above the specification when the CAN signal is P or N range.
―  Keyless control module detects that the TR switch stuck ON.
•  Starter monitor input voltage is less than the specification when the CAN signal is R or D range.
POSSIBLE CAUSE
•  Multiplex communication system DTC is stored
•  Starter relay malfunction
•  TR switch connector or terminals malfunction
•  TR switch malfunction
•  Keyless control module connector or terminals malfunction
•  Short to ground in wiring harness between the following terminals:
―  Starter relay terminal A—Keyless control module terminal 2F
―  Starter relay terminal A—TR switch terminal F
―  TR switch terminal A—Keyless control module terminal 3T
•  Short to power supply in wiring harness between the following terminals:
―  Starter relay terminal A—Keyless control module terminal 2F
―  Starter relay terminal A—TR switch terminal F
―  TR switch terminal A—Keyless control module terminal 3T
•  Open circuit in wiring harness between the following terminals:
―  Starter relay terminal A—Keyless control module terminal 2F
―  Starter relay terminal A—TR switch terminal F
―  TR switch terminal A—Keyless control module terminal 3T
•  Keyless control module malfunction

Diagnostic Procedure

Step

Inspection

Action

1
CONFIRM MULTIPLEX COMMUNICATION SYSTEM DTC
•  Perform the advanced keyless entry and push button start system DTC inspection using the M-MDS.
•  Are any multiplex communication system DTCs present?
Yes
Go to the applicable DTC inspection.
No
Go to the next step.
2
INSPECT STARTER RELAY
•  Switch the ignition to off.
•  Disconnect the negative battery cable.
•  Remove the starter relay.
•  Inspect the starter relay.
•  Is there any malfunction?
Yes
Replace the relay, then go to Step 9.
No
Go to the next step.
3
INSPECT TR SWITCH CONNECTOR AND TERMINALS
•  Disconnect the TR switch connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 9.
No
Go to the next step.
4
INSPECT TR SWITCH
•  Reconnect the TR switch connector.
•  Reconnect the negative battery cable.
•  Inspect the TR switch.
•  Is there any malfunction?
Yes
Replace the TR switch, then go to Step 9.
No
Go to the next step.
5
INSPECT KEYLESS CONTROL MODULE CONNECTOR AND TERMINALS
•  Disconnect the negative battery cable.
•  Disconnect the keyless control module connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 9.
No
Go to the next step.
6
INSPECT TR SWITCH CIRCUIT FOR SHORT TO GROUND
•  Starter relay is removed, and keyless control module connector is disconnected.
•  Disconnect the TR switch connector.
•  Inspect for continuity between the following terminals (wiring harness-side) and body ground:
―  Starter relay terminal A
―  TR switch terminal A
•  Is there continuity?
Yes
Repair or replace the wiring harness for a possible short to ground, then go to Step 9.
No
Go to the next step.
7
INSPECT TR SWITCH CIRCUIT FOR SHORT TO POWER SUPPLY
•  Starter relay is removed, and TR switch and keyless control module connectors are disconnected.
•  Reconnect the negative battery cable.
•  Switch the ignition to ON.
•  Measure the voltage at the following terminals (wiring harness-side):
―  Starter relay terminal A
―  TR switch terminal A
•  Is there any voltage?
Yes
Repair or replace the wiring harness for a possible short to power supply, then go to Step 9.
No
Go to the next step.
8
INSPECT TR SWITCH CIRCUIT FOR OPEN CIRCUIT
•  Starter relay is removed, and TR switch and keyless control module connectors are disconnected.
•  Switch the ignition to off.
•  Disconnect the negative battery cable.
•  Inspect for continuity between the following terminals (wiring harness-side):
―  Starter relay terminal A—Keyless control module terminal 2F
―  Starter relay terminal A—TR switch terminal F
―  TR switch terminal A—Keyless control module terminal 3T
•  Is there continuity?
Yes
Go to the next step.
No
Repair or replace the wiring harness for a possible open circuit, then go to the next step.
9
VERIFY TROUBLESHOOTING COMPLETED
•  Make sure to reconnect the disconnected connectors.
•  Reconnect the negative battery cable.
•  Operate the advanced key to activate the keyless control module.
•  Clear the DTC from the keyless control module using the M-MDS.
•  Switch the ignition to ON using the advanced key.
•  Perform the advanced keyless entry and push button start system DTC inspection using the M-MDS.
•  Is the same DTC present?
Yes
Replace the keyless control module, then go to the next step.
No
Go to the next step.
10
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.