POWER WINDOW SYSTEM OPERATION
id091200101100
Manual Open/Close
Auto-Open/Close
Auto Reverse Pinch Protection Function
IG OFF Timer
Fail-safe
Malfunction condition |
IG SW ON |
IG SW OFF |
Recovery condition |
---|---|---|---|
Hall effect switch 1 (for jam-safe and window position detection) operation malfunction
• During up/down movement, Hall effect switch 2 pulse detected but Hall effect switch 1 pulse not detected
|
Automatic operation prohibited
|
Auto and manual operation are prohibited
|
During up movement, pulse signals for Hall effect switches 1 and 2 detected normally, and fully closed position return/non-return ranges redetected
|
Hall effect switch 2 (for window movement direction detection) operation malfunction
• During up/down movement, Hall effect switch 1 pulse detected but Hall effect switch 2 pulse not detected
|
|||
Pulse signal malfunction detected (Inversion of input signals of or large phase deviation between pulses 1 and 2)
• During up/down movement, difference detected between the direction signals from Hall effect switches 1 and 2, and actual direction
|
|||
Non-return range downturn malfunction
• During up movement, the signal input from Hall effect switch 1 higher than the position stored in the P/W main switch
|
|||
Hall effect switch 1 and 2 operation malfunction
• Hall effect switches 1 and 2 pulse signal not detected after down movement initialed from the fully closed position
|