RVM SWITCH INSPECTION


id092200163300

1.  Disconnect the negative battery cable.

2.  Remove the RVM switch. (See RVM SWITCH REMOVAL/INSTALLATION.)

3.  Verify that the continuity between the RVM switch terminals is as indicated in the table.

am6zzw00004466
am6zzw00004467

•  If not as indicated in the table, replace the RVM switch.
am6zzw00004468
am6zzw00004469

4.  Apply battery positive voltage to RVM switch terminal E, and connect terminal A to ground.

5.  Verify that the LED illuminates.

•  If there is any malfunction, replace the RVM switch.