CONTROL SYSTEM PERSONALIZATION FEATURES SETTING PROCEDURE


id094000439800

Note
•  Use the IDS (laptop PC) because the PDS (Pocket PC) does not support the PERSONALIZATION FEATURES SETTING PROCEDURE.

1.  Connect the M-MDS to the DLC-2.

am3uuw00004713

2.  After the vehicle is identified, select the following items from the initial screen of the M-MDS.

•  When using the IDS (laptop PC)
1.  Select the “Module Programming”.

3.  Then, select items from the screen menu in the following order.

1.  Select “Programmable Parameters”.
2.  Select “Personality”, “Interior lighting” or “Washer/Wiper”.

4.  Select an item name, and then select option.

Items of “Personality”

M-MDS display

Function

Initial setting

Setting content

Control unit

Smart turn
The turn light system function can be set.
Enabled
Disabled / Enabled
BCM
Room lamp control time (when door closed)
The elapsed time between the doors closing and the interior light turning off can be adjusted.
15s
7.5s / 15s / 30s / 60s
BCM
Room lamp control time (when door unlocked)
The elapsed time between the doors unlocking and the interior light turning off can be adjusted.
30s
7.5s / 15s / 30s / 60s
BCM
Auto relock timer (without AKE)
Auto re-lock operation timing can be changed.
30sec
30sec / 60sec / 90sec
BCM
Rear defroster off timer
Rear defroster off timer operation timing can be changed.
15min
15min / 20min / 25min / 30min
BCM
Answer feed back (hazard)
Answer back hazard can be set to inoperable.
Enabled
Enabled / Disabled
BCM
Super lock (without AKE)
Super lock can be set to inoperable.
Enabled
Enabled / Disabled
BCM

Items of “Interior lighting”

M-MDS display

Function

Initial setting

Setting content

Control unit

Auto room lamp (when IG-OFF)
The automatic illumination function of the interior light after the ignition is switched off can be canceled.
Enabled
Enabled / Disabled
BCM
Auto room lamp (when doors unlocked)
The automatic illumination function of the interior light when the doors are unlocked can be canceled.
Enabled
Enabled / Disabled
BCM
Room Lamp Battery Saver Timer
The elapsed time for the interior light to automatically turn off when a door is ajar can be adjusted.
30min
30min / 60min / 10min
BCM
Room Lamp Battery Saver
The automatic illumination function of the interior light to automatically turn off can be canceled.
Enabled
Enabled / Disabled
BCM
Interactive illumination
The welcome mode can be set to operable or inoperable.
Enabled
Enabled / Disabled
BCM

Items of “Washer/Wiper”

M-MDS display

Function

Initial setting

Setting content

Control unit

Front wiper interlocked to window washer switch
The wiper action in conjunction with the windshield washer operation can be canceled.
Enabled
Enabled / Disabled
BCM
Rear wiper interlocked to window washer switch
The wiper action in conjunction with the rear washer operation can be canceled.
Enabled
Enabled / Disabled
BCM