SIMULATION TEST[MZ-CD 1.6 (Y6)]


id0102c3100600

•  The simulation items are shown below.

Simulation item table (PCM)

×: Applicable
—: Not applicable

Item

Applicable component

Unit/Condition

Test condition

PCM terminal

KOEO

KOER

ALTF
Generator field current control duty signal
On/Off
×
107
CABVP
Air bypass valve position sensor
%
×
×
233
EGR _TV
Intake throttle valve
%
×
×
247
EgrDc
EGR valve duty cycle
%
×
×
228
FAN_DUTY
Fan control duty value
%
×
×
318
FP
Fuel pump relay
%
×
212
GPC
Glow plug relay
On/Off
×
×
210
ST_EN_RLY
Stater relay
Enabled/Disabled
×
×
108
VBCV
VBC solenoid valve
%
×
×
104

Simulation item table (fuel additive control module)

×: Applicable
—: Not applicable

Item

Applicable component

Unit/Condition

Test condition

Fuel additive control module terminal

KOEO

KOER

ADD_PUMP
Fuel additive pump unit driving state
On/Off
9
GAUGING
Fuel additive gauging stage
On/Off