AIR CLEANER CONSTRUCTION[ZJ, ZY, Z6]


id0113b1101400

•  The air cleaner is mainly composed of the air cleaner case, air cleaner cover and air cleaner element.
Air Cleaner Element
•  Non-woven fabric (dry type) has been adopted.
Air Cleaner Construction
•  The air cleaner construction suppresses intake air resistance for increased torque at all engine speeds.
Air Cleaner Cover
•  The PCM and attached PCM case have been integrated with the cover. The PCM is forced cooled by intake air due to this integration. (See PCM CONSTRUCTION/OPERATION[ZJ, ZY, Z6].)
am3zzn00000701

1
Air cleaner cover
2
Air cleaner element
3
Air cleaner case