GENERATOR INSPECTION[ZJ, ZY, Z6]
id0117c1800300
Generator Warning Light
1. Verify that the battery is fully charged.
2. Verify that the drive belt deflection/tension is correct. (See DRIVE BELT INSPECTION[ZJ, ZY, Z6].)
3. With the ignition switch at ON, verify that the generator warning light illuminates.
4. Verify that the generator warning light goes off after the engine is started.
Generator
Voltage
1. Verify that the battery is fully charged.
2. Verify that the drive belt deflection/tension is correct. (See DRIVE BELT INSPECTION[ZJ, ZY, Z6].)
3. Turn off all electrical loads.
4. Start the engine and verify that the generator rotates smoothly without any noise while the engine is running.
5. Measure the voltage at each terminal using a tester.
am3zzw00000399
|
Current
1. Verify that the battery is fully charged.
2. Verify that the drive belt deflection/tension is correct. (See DRIVE BELT INSPECTION[ZJ, ZY, Z6].)
3. Disconnect the negative battery cable.
4. Connect a tester capable of reading 120 A or more between generator terminal B and the wiring harness.
5. Connect the negative battery cable.
6. Turn off all electrical loads.
7. Start the engine.
8. Increase engine speed to 2,500 rpm.
9. Turn the following electrical loads on and verify that the current reading increases more than the minimum value indicated below.
PCM and generator shearing inspection
1. Inspect as follows:
Step |
Inspection |
Action |
||
---|---|---|---|---|
1
|
Measure the generator terminal B voltage when the electrical loads*1 are on and off.
|
15 V or more
|
Go to Step 2.
|
|
13—15 V
|
Normal*2
|
|||
13 V or less
|
Go to Step 3.
|
|||
2
|
Monitor the ALTTV PID using M-MDS, or measure the voltage of PCM terminal 2AR (without throttle valve actuator), 2AE (with throttle valve actuator) using a tester. Is the voltage between 13 and 15 V ?
|
Yes
|
Go to Step 4.
|
|
No
|
PCM input error.
|
|||
3
|
Monitor the ALTTV PID using M-MDS, or measure the voltage of PCM terminal 2AR (without throttle valve actuator), 2AE (with throttle valve actuator) using a tester. Is the voltage between 13 and 15 V ?
|
Yes
|
Go to Step 5.
|
|
No
|
PCM input error.
|
|||
4
|
Monitor the ALTF PID using M-MDS, or calculate the duty value of the PCM terminal 2AN (without throttle valve actuator), 2AF (with throttle valve actuator) using oscilloscope. Is the duty value 100% ?
|
![]() |
Yes
|
PCM input error.
|
No
|
PCM, generator, or both are not normal.
|
|||
5
|
Monitor the ALTF PID using M-MDS, or calculate the duty value of the PCM terminal 2AN using oscilloscope. Is the duty value 0% ?
|
![]() |
Yes
|
PCM input error.
|
No
|
PCM, generator, or both are not normal.
|
Generator Inner Parts
Rotor
1. Measure the resistance between the slip rings using an ohmmeter.
am3zzw00001336
|
2. Verify that there is no continuity between the slip ring and core using an ohmmeter.
am3zzw00001337
|
3. Inspect the slip ring surface condition.
Stator coil
1. Inspect for continuity between the stator coil leads using an ohmmeter.
am3zzw00001338
|
2. Verify that there is no continuity between the stator coil leads and the core using an ohmmeter.
am3zzw00001339
|
Brush
1. Inspect brushes for wear.
am3zzw00001340
|
Brush spring
1. Measure the force of the brush spring using a spring pressure gauge.
2. Read the spring pressure gauge at the brush tip projection of 2 mm {0.079 in}.
am3zzw00001341
|
Rectifier (without throttle valve actuator)
1. Inspect for continuity of the diodes using an ohmmeter.
am3zzw00001342
|
am3zzw00001343
|
Specification
Tester |
Continuity |
|
---|---|---|
Negative |
Positive |
|
E
|
P1, P2, P3, P4
|
Yes
|
B
|
No
|
|
P1, P2, P3, P4
|
E
|
No
|
B
|
Yes
|
Rectifier (with throttle valve actuator)
1. Inspect for continuity of the diodes using an ohmmeter.
avejjw00000094
|
avejjw00000095
|
Specification
Tester |
Continuity |
|
---|---|---|
Negative |
Positive |
|
E
|
P1, P2, P3
|
Yes
|
B
|
No
|
|
P1, P2, P3
|
E
|
No
|
B
|
Yes
|
Bearing
1. Inspect for abnormal noise, looseness, and sticking.
am3zzw00001344
|