EGR CONTROL OPERATION[LF, L3]
id0140a9171600
Stepping motor operation principles
Energization condition for each coil
When current step number divided by four |
Evenly divisible |
One leftover |
Two leftover |
Three leftover |
---|---|---|---|---|
Coil No.1
|
ON
|
ON
|
OFF
|
OFF
|
Coil No.2
|
OFF
|
OFF
|
ON
|
ON
|
Coil No.3
|
OFF
|
ON
|
ON
|
OFF
|
Coil No.4
|
ON
|
OFF
|
OFF
|
ON
|
Example of energization condition for each coil and step number
Step number |
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
30 |
52 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Coil No.1
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
Coil No.2
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
Coil No.3
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
ON
|
OFF
|
Coil No.4
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
ON
|
Control outline
Target EGR valve position
Target EGR valve position determination table
Contents |
Method for calculating or determining the EGR valve position and correction |
|
---|---|---|
Basic EGR valve position
|
Within steps 0—52 in the stepping motor determined as follows:
• When the engine speed is 1,187—4,200 rpm and the charging efficiency*1 is within 12.5—75%, the engine speed and charging efficiency are determined to be at basic position
• When the EGR control inhibition conditions are met, step 0
|
|
Correction *2
|
Engine coolant temperature correction
|
Purpose: Improved driveability
Engine coolant temperature is 50—55 °C {122—131 °F}
• The step number is restricted between 0—50 % of the basic EGR valve position (low engine coolant temperature—low step number) according to the engine coolant temperature.
Engine coolant temperature is 55—65 °C {131—149 °F}
• The step number is restricted between 50—100 % of the basic EGR valve position (low engine coolant temperature→low step number) according to the engine coolant temperature.
|
Intake air temperature correction
|
Purpose: Improved driveability
Intake air temperature is 50 °C {122 °F} or less
• Step number is restricted to 100 % of the basic EGR valve position (basic EGR valve position = step number)
Intake air temperature is 50 °C {122 °F} or more
• Step number is restricted between 40—100 % of basic EGR valve position (low intake air temperature→large step number)
|
|
Acceleration/deceleration correction
|
Purpose: Improved driveability
During acceleration/deceleration, when the throttle valve opening angle fluctuation rate is the set value or more
• During acceleration→step number is restricted to 20 % of basic EGR valve position
• During deceleration→step number is restricted to 0 % of basic EGR valve position
|
Inhibition conditions