CLUTCH PEDAL POSITION (CPP) SWITCH INSPECTION[LF, L3]
id0140a9801600
MTX
Continuity Inspection
1. Remove the CPP switch.
2. Verify that the continuity between CPP switch terminals A and B is as indicated in the table.
am3zzw00001744
|
Measurement condition |
Continuity |
---|---|
Push the rod.
|
Continuity detected
|
Except above
|
No continuity
|
Circuit Open/Short Inspection
am3zzw00001745
|
acxuuw00000119
|
1. Disconnect the PCM connector.
2. Disconnect the CPP switch connector.
3. Inspect the following wiring harnesses for open or short circuit. (Continuity inspection)