CLUTCH PEDAL POSITION (CPP) SWITCH CONSTRUCTION/OPERATION[ZJ, ZY, Z6]


id0140b1177700

•  When the clutch pedal is depressed, the contact closes (ON) and the PCM detects a voltage of 1.0 V or less. When the clutch pedal is not depressed, the contact opens (OFF) the PCM detects a voltage of B+.
am3zzn00000373

1
CPP switch
2
Push OFF
3
Clutch pedal not depressed (OFF)
4
Clutch pedal depressed (ON)
5
Clutch pedal depressed (ON)
6
Clutch pedal not depressed (OFF)
7
No load
8
Load