NEUTRAL SWITCH INSPECTION (MTX)[ZJ, ZY, Z6]
id0140b1800000
-
Note
-
• Before performing the following inspection, make sure to follow the procedure as indicated in the troubleshooting flowchart. (See
HOW TO USE THIS MANUAL).
Continuity Inspection
1. Remove the neutral switch.
2. Verify that the continuity between neutral switch terminals A and B is as indicated in the table.
-
• If the monitor item condition/specification (reference) is not within the specification, even though there is no malfunction, perform the “Circuit Open/Short Inspection”.
Circuit Open/Short Inspection (Without Throttle Valve Actuator)
1. Remove the PCM connector cover.
2. Disconnect the PCM connector. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION[ZJ, ZY, Z6].)
3. Inspect the following wiring harness for open or short circuit (continuity check).
Open circuit
-
• If there is no continuity, there is an open circuit. Repair or replace the wiring harness.
-
― Neutral switch terminal A and PCM terminal 1AB
― Neutral switch terminal B and body ground
Short circuit
-
• If there is continuity, there is a short circuit. Repair or replace the wiring harness.
-
― Neutral switch terminal A and body ground
― Neutral switch terminal B and power supply
Circuit Open/Short Inspection (With Throttle Valve Actuator)
1. Remove the PCM connector cover.
2. Disconnect the PCM connector. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION[ZJ, ZY, Z6].)
3. Inspect the following wiring harness for open or short circuit (continuity check).
Open circuit
-
• If there is no continuity, there is an open circuit. Repair or replace the wiring harness.
-
― Neutral switch terminal A and PCM terminal 1J
― Neutral switch terminal B and body ground
Short circuit
-
• If there is continuity, there is a short circuit. Repair or replace the wiring harness.
-
― Neutral switch terminal A and body ground
― Neutral switch terminal B and power supply