NEUTRAL SWITCH INSPECTION[L3 Turbo]


id0140b6800800

Note
•  Before performing the following inspection, make sure to follow the procedure as indicated in the troubleshooting flowchart.

Continuity Inspection

1.  Remove the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION[A26M-R].)

2.  Verify that the continuity between neutral switch terminals A and B is as indicated in the table.

am3uuw00000126

•  If it can be verified, perform the “Circuit Open/Short Inspection”.
•  If it cannot be verified, replace the neutral switch.

Measured condition

Continuity

Rod pushed
Continuity detected
Except above
No continuity


Circuit Open/Short Inspection

am3uuw00000127
e3u140zw6991

1.  Disconnect the PCM connector.

2.  Inspect the following wiring harness for an open or short circuit. (Continuity inspection)


Open circuit

•  If there is no continuity in the following wiring harnesses, there is an open circuit. Repair or replace the wiring harness.
―  Neutral switch terminal A and PCM terminal 1S
―  Neutral switch terminal B and body ground


Short circuit

•  If there is continuity in the following wiring harnesses, there is a short circuit. Repair or replace the wiring harness.
―  Neutral switch terminal B and ground