EGR CONTROL OPERATION [MZR-CD (RF Turbo)]
id0140f1171600
• The PCM calculates the necessary EGR amount and oxygen concentration based on the input signal, and operates the EGR valve (DC motor) to meet the target value.
• The EGR amount is determined by the difference between the following values:
-
― Target intake air amount calculated from engine speed and fuel injection amount.
― Actual intake air amount detected by MAF/IAT sensor.
• Oxygen concentration is determined by the difference between the following values:
-
― Target intake air amount calculated from engine speed and fuel injection amount.
― Actual intake air amount detected by MAF/IAT sensor, boost sensor, and A/F sensor.