EGR VALVE POSITION SENSOR INSPECTION [MZR-CD (RF Turbo)]
id0140f1807600
Voltage Inspection
1. Turn the engine switch to ON.
2. Monitor the EGRP PID using the M-MDS.
3. Start the engine and warm up the engine completely.
4. Monitor the EGRP PID using the M-MDS at idle.
Circuit Open/Short Inspection
1. Disconnect the PCM connector. (See PCM REMOVAL/INSTALLATION [MZR-CD (RF Turbo)].)
2. Disconnect the EGR valve connector.
3. Inspect for open/short circuit in the following wiring harnesses.
am3zzw00004103
|
Open circuit
Short circuit