BAROMETRIC PRESSURE (BARO) SENSOR INSPECTION [MZR-CD (RF Turbo)]


id0140f1818700

Note
•  Perform the following inspection only when directed.
•  The following vacuum values are indicated by relative pressure from the PCM. (See PCM REMOVAL/INSTALLATION [MZR-CD (RF Turbo)].)

1.  Connect the M-MDS to the DLC‐2.

2.  Turn the engine switch to ON.

3.  Select BARO on the M-MDS.

4.  Verify that the BARO PID (pressure) and barometric pressure are practically equal.

•  If not as verified, perform the “Circuit Open/Short Inspection”.
―  If there is no open or short circuit, replace the PCM. (See PCM REMOVAL/INSTALLATION [MZR-CD (RF Turbo)].)