PARAMETER IDENTIFICATION (PID) DATA MONITORING FUNCTION[FN4A-EL]


id0502a1100700

•  The PID mode allows access to certain data values, analog and digital input and output, calculations and system state information.

Monitor item table

Display on the tester

Definition

Unit/Condition

PCM terminal

ZY

Z6

LF

DTCCNT
Number of DTC detected
N/A
N/A
N/A
N/A
DWN SW
Down switch
On/Off
1J
1AB
1P
GEAR
Gear commanded by module
1/2/3/4
N/A
N/A
N/A
HTM_CNT
Indicates number of high oil temperature mode (ATF temperature at 130 °C {266 °F} or more) operations
N/A
N/A
N/A
N/A
HTM_DIS
Indicates travel distance after operation of high oil temperature mode (ATF temperature at 130 °C {266 °F} or more)
km
N/A
N/A
N/A
LINEDES
Target line pressure
Pa
N/A
N/A
N/A
LPS
Pressure control solenoid control signal in PCM
A
1P, 1T
1AV, 1AF
1H, 1G
MNL SW
M range switch
On/Off
1N
1AQ
1O
OSS
Output shaft speed
RPM
1AX
1AY
1J
SSA/SS1
Shift solenoid A control signal in PCM
%
1D
1AZ
1B
SSB/SS2
Shift solenoid B control signal in PCM
%
1H
1BH
1C
SSC/SS3
Shift solenoid C control signal in PCM
%
1L
1BD
1D
SSD/SS4
Shift solenoid D control signal in PCM
On/Off
1K
1AJ
1E
SSE_SS5
Shift solenoid E control signal in PCM
On/Off
1O
1AR
1F
TFT
ATF temperature
°C
1AH
1AU
1U
TFTV
ATF temperature signal voltage
V
1AH
1AU
1U
THOP
Throttle position signal in PCM
%
2AT, 2AX
2AA
2I, 2M
TR
Transaxle range
P/R/N/D
1AS
1X
1S
TR_SENS
TR switch
V
1AS
1X
1S
TSS
Input/turbine speed
RPM
1R, 1V
1O, 1K
1M, 1Q
UP SW
Up switch
On/Off
1M
1P
1K