INPUT/TURBINE SPEED SENSOR INSPECTION[FS5A-EL]


id051721801200

Caution
•  Water or foreign objects entering the connector can cause a poor connection or corrosion. Be sure not to drop water or foreign objects on the connector when disconnecting it.

1.  Remove the battery duct and battery cover. (See BATTERY REMOVAL/INSTALLATION[LF, L3].)

2.  Disconnect the negative battery cable.

3.  Remove the battery, battery box and battery tray. (See BATTERY REMOVAL/INSTALLATION[LF, L3].)

4.  Remove the air cleaner component. (See INTAKE AIR SYSTEM REMOVAL/INSTALLATION[LF, L3].)

5.  Disconnect the input/turbine speed sensor connector.

am3zzw00003423

6.  Measure resistance between the terminals of the input/turbine speed sensor.

am3zzw00003424

•  If not as specified, replace the input/turbine speed sensor.
Input/turbine speed sensor resistance
250—600 ohms (ATF temperature: –40—160 °C {–40—320 °F})

7.  Connect the input/turbine speed sensor connector.

8.  Install the air cleaner component. (See INTAKE AIR SYSTEM REMOVAL/INSTALLATION[LF, L3].)

9.  Install the battery, battery box and battery tray. (See BATTERY REMOVAL/INSTALLATION[LF, L3].)

10.  Connect the negative battery cable.

11.  Install the battery duct and battery cover. (See BATTERY REMOVAL/INSTALLATION[LF, L3].)