DTC B1260, B1261, B1274, B1275, B1282, B1283 (MULTIPLE DTCS INDICATED)
id070200800700
DTC B1260, B1261, B1282, B1283, B1274, B1275 |
Climate control unit (+5 V power supply) system |
---|---|
POSSIBLE CAUSE
|
• Open or short circuit in wiring harnesses between climate control unit and solar radiation sensor, air mix actuator, or airflow mode actuator
|
Diagnostic Procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Disconnect the climate control unit connector and the airflow mode actuator connector.
• Is there an open circuit in the wiring harness between climate control unit terminal P and airflow mode actuator terminal A?
|
Yes
|
Repair the wiring harness.
|
No
|
Go to the next step.
|
||
2
|
• Is there a short circuit to ground in the wiring harness between climate control unit terminal P and airflow mode actuator terminal A?
|
Yes
|
Repair the wiring harness.
|
No
|
Go to the next step.
|
||
3
|
• Is there a short circuit to ground in the wiring harness between climate control unit terminal P and air mix actuator terminal A?
|
Yes
|
Repair the wiring harness.
|
No
|
Go to the next step.
|
||
4
|
• Is there a short circuit to ground in the wiring harness between climate control unit terminal P and solar radiation sensor terminal A?
|
Yes
|
Repair the wiring harness.
|
No
|
The system is normal at present. (Clear the past malfunction from the memory.)
|
||
![]() |