DTC B1947, B2014


id070200801000

DTC B1947, B2014

Evaporator temperature sensor system

POSSIBLE CAUSE
•  Evaporator temperature sensor malfunction
•  Open or short circuit in wiring harness between climate control unit and evaporator temperature sensor

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
•  Inspect the evaporator temperature sensor. (See EVAPORATOR TEMPERATURE SENSOR INSPECTION.)
•  Is it normal?
Yes
Go to the next step.
No
Replace the evaporator temperature sensor. (See EVAPORATOR TEMPERATURE SENSOR REMOVAL/INSTALLATION.)
2
•  Disconnect the climate control unit connector and the evaporator temperature sensor connector.
•  Is there an open circuit in the wiring harness between the following terminals of the climate control unit and the evaporator temperature sensor?
―  Climate control unit terminal T—Evaporator temperature sensor terminal B
―  Climate control unit terminal U—Evaporator temperature sensor terminal A
Yes
Repair the wiring harness.
No
Go to the next step.
3
•  Is there a short circuit to ground in the wiring harness between climate control unit terminal T and evaporator temperature sensor terminal B?
Yes
Repair the wiring harness.
No
Connect the climate control unit connector, then go to the next step.
4
•  Turn the ignition switch to the ON position.
•  Inspect the voltage at the following climate control unit terminal (wiring harness-side).
―  Terminal T (evaporator temperature sensor input signal)
•  Is the voltage normal? (approx. 5 V)
Yes
The system is normal at present. (Clear the past malfunction from the memory.)
No