NO.6 WINDSHIELD FOGGED
id070300800900
Full-auto Air Conditioner, Manual Air Conditioner (Wtih air intake actuator)
6
|
Windshield fogged.
|
DESCRIPTION
|
• A/C compressor does not operate while airflow mode is in DEFROSTER or HEAT/DEF modes.
• Air intake mode does not change to FRESH while airflow mode is in DEFROSTER or HEAT/DEF modes.
|
POSSIBLE CAUSE
|
• Climate control unit (B+ signal) system malfunction (Steps 2, 4, 5)
• Air intake actuator malfunction (Steps 3, 7)
• Climate control unit (RECIRCULATE, FRESH signal) system malfunction (Steps 9—11)
• A/C unit air intake door malfunction (Steps 12, 13)
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
COOL AIR BLOW OUT INSPECTION
• When both the A/C and fan switch in the climate control unit are on, does cool air blow out from the front vent?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 1 of troubleshooting index No.8.
|
||
2
|
INSPECT CLIMATE CONTROL UNIT POWER SUPPLY FUSE FOR B+ SIGNAL
• Is the climate control unit power supply fuse for B+ signal normal?
|
Yes
|
Go to the next step.
|
No
|
Inspect for a short to ground on blown fuse circuit.
• Repair or replace if necessary. Install appropriate amperage fuse.
|
||
3
|
INSPECT AIR INTAKE ACTUATOR
• Inspect the air intake actuator.
• Are the above items normal?
|
Yes
|
Go to the next step.
|
No
|
Apply grease or install the link properly and securely, remove obstruction, then go to Step 14.
|
||
*4
|
INSPECT WIRING HARNESS BETWEEN FUSE BLOCK AND CLIMATE CONTROL UNIT FOR CONTINUITY
• Disconnect the climate control unit connector (24-pin).
• Turn the ignition switch to the ON position.
• Measure the voltage at climate control unit terminal J (full-auto air conditioner) / D (manual air conditioner) (B+ signal).
• Is the voltage approx. 12 V?
|
Yes
|
Go to the next step.
|
No
|
Repair the wiring harness between the fuse block and climate control unit, then go to Step 14.
|
||
*5
|
INSPECT WIRING HARNESS BETWEEN CLIMATE CONTROL UNIT AND GROUND FOR VOLTAGE
• Measure the voltage at climate control unit terminal V (Ground).
• Is the voltage approx. 0V?
|
Yes
|
Go to the next step.
|
No
|
Repair the wiring harness between the climate control unit and ground, then go to Step 14.
|
||
6
|
VERIFY WHETHER MALFUNCTION IS IN A/C UNIT AIR INTAKE DOOR OR ELSEWHERE
• Turn the ignition switch to the LOCK position.
• Connect the climate control unit connector (24-pin).
• Remove the air intake actuator.
• Turn the ignition switch to the ON position.
• Set the fan switch to 4th position.
• Does the air intake mode (RECIRCULATE, FRESH) change smoothly when the air intake link is operated by hand?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 12.
|
||
7
|
INSPECT AIR INTAKE ACTUATOR
• Inspect the air intake actuator.
• Is it normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the air intake actuator, go to Step 14.
|
||
8
|
INSPECT AIR INTAKE SELECTOR SWITCH AND DEFROSTER SWITCH IN CLIMATE CONTROL UNIT
• Measure the voltage at climate control unit connector (24-pin) terminals O and Q.
• Is it normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the climate control unit, then go to Step 14.
|
||
*9
|
INSPECT WIRING HARNESS BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR FOR CONTINUITY
• Turn the ignition switch to the LOCK position.
• Is there continuity between the following climate control unit terminals and air intake actuator terminals?
|
Yes
|
Go to the next step.
|
No
|
Repair the wiring harness between the climate control unit and air intake actuator, then go to Step 14.
|
||
*10
|
INSPECT WIRING HARNESS BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR FOR SHORT TO GROUND
• Is there continuity between the following climate control unit terminals and ground?
|
Yes
|
Repair the wiring harness between the climate control unit and air intake actuator, then go to Step 14.
|
No
|
Go to the next step.
|
||
*11
|
INSPECT WIRING HARNESS BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR FOR SHORT TO B+
• Turn the ignition switch to the ON position
• Measure the voltage at the following climate control unit terminals.
• Is the voltage approx. 12 V?
|
Yes
|
Repair the wiring harness between the climate control unit and air intake actuator, then go to Step 14.
|
No
|
Replace the climate control unit, then go to Step 14.
|
||
12
|
INSPECT A/C UNIT AIR INTAKE DOOR
• Is there any foreign material or obstruction in the A/C unit air intake door?
|
Yes
|
Remove obstruction, then go to Step 14.
|
No
|
Go to the next step.
|
||
13
|
VERIFY THAT A/C UNIT AIR INTAKE DOOR IS POSITIONED SECURELY AND PROPERLY
• Is the A/C unit air intake door securely and properly positioned?
|
Yes
|
Inspect the air intake door for cracks or damage, then go to the next step.
|
No
|
Install the air intake door securely in the proper position, then go to the next step.
|
||
14
|
VERIFY THAT MALFUNCTION SYMPTOM OCCURS AFTER REPAIR
• Does the malfunction disappear?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.
|
Manual Air Conditioner (Wtihout air intake actuator)
6
|
Windshield fogged.
|
DESCRIPTION
|
• Air does not blow when airflow mode is in DEFROSTER or HEAT/DEF modes.
|
POSSIBLE CAUSE
|
• Airflow mode wire, wire clamp malfunction (Step 1)
• Climate control unit rack-and-piston, airflow mode wire malfunction (Step 2)
• A/C unit airflow mode door malfunction (Step 3, 4)
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
VERIFY AIR INTAKE WIRE FROM A/C UNIT IS POSITIONED SECURELY AND CORRECTLY
• Is the airflow mode wire securely installed in the correct position in relation to the A/C unit air intake links?
|
Yes
|
Go to the next step.
|
No
|
Adjust the airflow mode wire or install securely in the correct position, then go to Step 5.
|
||
2
|
INSPECT CLIMATE CONTROL UNIT
• Remove the intake wire from A/C unit.
• Inspect climate control unit airflow mode control dial operation.
• Does the air intake lever move smoothly?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the climate control unit, then go to Step 5.
|
||
3
|
INSPECT A/C UNIT
• Is there any foreign material or obstruction in the A/C unit airflow mode door?
|
Yes
|
Remove obstruction, then go to Step 5.
|
No
|
Go to the next step.
|
||
4
|
INSPECT A/C UNIT AIRFLOW MODE DOOR
• Is the A/C unit airflow mode door securely and properly installed?
|
Yes
|
Inspect the airflow mode door for cracks or damage, then go to the next step.
|
No
|
Install the airflow mode door securely in the proper position, then go to the next step.
|
||
5
|
VERIFY THAT MALFUNCTION SYMPTOM OCCURS AFTER REPAIR
• Does the malfunction disappear?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.
|