ACCUMULATOR CONSTRUCTION[MZ-CD 1.6 (Y6)]
id0711b1101200
Construction
• The accumulator stabilizes the vaporized refrigerant and supplies it to the A/C compressor.
• The accumulator stores the refrigerant temporarily and extracts the vaporized refrigerant. Thus, it prevents refrigerant that cannot be completely vaporized from flowing out to the A/C compressor.
• Desiccant inside the accumulator is used to remove moisture from the refrigerant.
• An oil return orifice is located at the bottom of the accumulator to return the compressor oil which accumulates there to the A/C compressor. Additionally, a filter located in front of the orifice removes foreign material inside the refrigerant cycle.