DTC B2973[PJB]
id090208836400
DTC B2973 |
Running light relay circuit failure |
---|---|
DETECTION CONDITION
|
Short to power supply or GND in PJB internal circuit between microcomputer and running light relay
|
POSSIBLE CAUSE
|
• Running light relay malfunction
• PJB malfunction
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT DTC
• Clear the DTC from the PJB memory using the M-MDS.
• Perform the self-test.
(See PJB SELF-TEST[PJB].)
• Is the same DTC present?
|
Yes
|
Go to the next step.
|
No
|
Troubleshooting completed.
|
||
2
|
INSPECT RUNNING LIGHT RELAY
• Inspect the running light relay.
(See RELAY INSPECTION.)
• Is there any malfunction?
|
Yes
|
Replace the running light relay, then go to the next step.
|
No
|
Go to the next step.
|
||
3
|
VERIFY TROUBLESHOOTING COMPLETED
• Make sure to reconnect all disconnected connectors.
• Clear the DTC from the PJB memory using the M-MDS.
• Perform the self-test.
(See PJB SELF-TEST[PJB].)
• Is the same DTC present?
|
Yes
|
Replace the PJB.
|
No
|
Troubleshooting completed.
|