DTC B1317/B1318 [ADVANCED KEYLESS SYSTEM]


id0902e2802400

DTC B1317

Keyless control module power supply voltage increases (16.1 V or more).

DTC B1318

Keyless control module power supply voltage decreases (less than 9 V).

POSSIBLE CAUSE
•  When the keyless control module power supply voltage is not within 9—16 V
POSSIBLE CAUSE
•  Open or short circuit in wiring harness between battery and keyless control module
•  Battery malfunction
•  Keyless control module malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1
INSPECT FUSE
•  Remove the ROOM fuse.
•  Is the fuse normal?
Yes
Go to the next step.
No
Replace the fuse.
2
INSPECT BATTERY
•  Measure the battery positive voltage.
•  Is the voltage 9 V—16 V?
Yes
Go to the next step.
No
The battery has a malfunction.
Inspect the charge/discharge system/
3
INSPECT WIRING HARNESS BETWEEN BATTERY AND KEYLESS CONTROL MODULE
•  Turn the ignition switch to the ON position.
•  Measure the keyless control module terminal 2A voltage
•  Is the voltage 9 V—16 V?
Yes
Replace the keyless control module and perform the resetting procedure for the advanced keyless system when replacing the keyless control module.
No
DTC troubleshooting completed.