POWER WINDOW SYSTEM OPERATION
id091200101100
Manual Open/Close
Auto-Open/Close
Auto Reverse Pinch Protection Function
Two-step down function
IG OFF Timer
Fail-safe
Malfunction condition |
IG SW ON |
IG SW OFF |
Recovery condition |
---|---|---|---|
Pulse 1 (for pinching and door glass position detection) stopping malfunction
• Pulse 2 pulse detected but pulse 1 not detected when opening or closing
|
Automatic operation is prohibited
|
Auto and manual operation are prohibited
|
Pulse signals 1 and 2 detected normally during close operation, and redetection of fully-closed position return/non-return ranges
|
Pulse 2 (for door glass direction detection) stopping malfunction
• Pulse 1 detected but pulse 2 is not detected during close or open operation
|
|||
Pulse signal malfunction detected (Inversion of input signals of or large phase deviation between pulses 1 and 2)
• Difference detected between the direction detected by the signals of pulses 1 and 2, and the actual direction
|
|||
Non-return range downturn malfunction
• The signal input from pulse 1 is higher than the position stored in the P/W main switch is detected during close operation
|
|||
Pulse 1 and 2 stopping malfunction
• Pulse signals 1 and 2 not detected after open operation initiated from the fully closed position
|