AUTO LEVELING CONTROL MODULE CONSTRUCTION/OPERATION
id091800103800
Optical axis adjustment function
Initial setting function
Fail-safe Function
Fail-safe function table
Item |
Test condition |
Fail-safe function |
Indicator light |
Cancel condition |
|
---|---|---|---|---|---|
Auto leveling sensor
|
Signal malfunction
|
When signal voltage of auto leveling sensor is 0.49 V or less, or 4.43 V or more, 3 or more times, for approx. 0.04 s is detected.
|
Returns to initial position if optical axis position is higher than initial position.
Stops optical axis position when malfunction is detected if optical axis position is lower than initial position.
|
Illuminated*1
|
When normal status continuous for 1 s or more, or the ignition switch is turned off and then to the ON position again.
|
Battery voltage
|
Excessive power supply voltage
|
When battery voltage of 10 V or less, or 16 V or more is detected
|
Stops at optical axis position when malfunction is detected.
|
Not illuminated
|
When battery voltage between 10-16 V is detected, or the ignition switch is turned off and then to the ON position again.
|
Auto leveling control module
|
When malfunction in auto leveling control module is detected.
|
Resets microcomputer in auto leveling control module.
|
Illuminated
|
When the ignition switch is turned off and then to the ON position again.
|
|
Headlight leveling actuator
|
When there is short to power supply or ground in harness between auto leveling control module and headlight leveling actuator
|
Stops at optical axis position when malfunction is detected.
|
Illuminated
|
When normal status continues for 1 s or more.
|