AUTO LEVELING SENSOR INSPECTION
id091800805600
1. Connect the three dry cell batteries in series.
am3zzw00001805
|
2. Connect the positive pole of the battery to auto leveling sensor terminal C, and the negative pole to terminal A.
3. Connect the tester as shown in the figure.
4. Measure the voltage while the link is moved up and down slowly.
Link angle (vehicle height) |
Voltage (V) |
---|---|
+45°(High)
|
4.1
|
0°
|
2.3
|
-45°(Low)
|
0.5
|