DATA MONITORING AND RECORDING PROCEDURE


id092200801500

1.  Connect the M-MDS or equivalent to the DLC-2 (16-pin).

am3zzw00001929

2.  After the vehicle is identified, select the following items from the initial screen of the M-MDS.

When using the IDS (laptop PC)
•  Select the “Toolbox” tab.
•  Select “DataLogger”.
•  Select “Modules”.
•  Select “IC”.
When using the PDS (Pocket PC)
•  Select “Module Tests”.
•  Select “IC”.
•  Select “DataLogger”.

3.  Verify the data monitor items.


Indication Item Table

Monitor item

Input-output signal/part name

Unit/State

Terminal

CCNT_HE
Number of continuous DTCs
ECT_GAUGE
Water temperature gauge
°F
°C
1I, 1K
NUMKEYS*
Number of key ID numbers registered with the vehicle
ODO COUNT
Odometer
m
1I, 1K
TACH
Tachometer
RPM
SPDOMETER
Speedometer
MPH
KPH

*  :With immobilizer system (without advanced keyless system)