FUEL PUMP UNIT INSPECTION [MZR 1.6]


id0114f4801100


Continuity Inspection

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [MZR 1.6].)

2.  Disconnect the fuel pump unit connector.

3.  Inspect for continuity between fuel pump unit terminals A—B.

ac5uuw00002666

•  If there is no continuity, replace the fuel pump. (See FUEL PUMP UNIT REMOVAL/INSTALLATION [MZR 1.6].)