MAIN RELAY CONTROL OPERATION [MZR 1.6]
id0140j7170200
• When the ignition is switched ON, the main relay turns on and power is supplied to sensors and devices.
• When the ignition is switched off from ON, a main relay on command signal is received the main relay turns on from the drive-by-wire control.
• When the on request signal from the drive-by-wire control stop, the main relay turns off.