CURRENT SENSOR [SKYACTIV-D 2.2]


id0140z7005000


Purpose/Function

•  The battery conditions are monitored as basic information for determining the generator output current.
•  The battery condition is send to the PCM by LIN communication via the front body control module (FBCM).

Construction

•  Installed to the negative battery cable.
am6zzn00001855
•  The current sensor has adopted shunt resistance on the detection area and a thermistor for detecting the battery condition.

Operation

•  The battery charge/discharge flow, battery voltage, and the battery terminal temperature are send to the PCM by LIN communication via the front body control module (FBCM).
am3zzn00005271

Fail-safe

DTC No.

Fail-safe function

P058A:00
•  Inhibits engine-stop by operating the i-stop function.
•  Inhibits engine-stop by operating the i-ELOOP function. (With i-ELOOP)
U1007:00
•  Inhibits engine-stop by operating the i-stop function.
•  Inhibits a part of the generator output control.