REFRIGERANT PRESSURE SENSOR [MANUAL AIR CONDITIONER]
id0740a2005400
Purpose, Function
Construction
am2zzn00002150
|
Operation
1. Pressure is applied to the ceramic diaphragm of the detection area according to the refrigerant pressure in the cooler pipe.
am2zzn00002151
|
2. The shape of the ceramic diaphragm changes by the applied pressure, and the amount of clearance between the electrodes changes.
3. The refrigerant pressure sensor detects the electrical load (capacitance) which changes according to the clearance amount, and converts it to a voltage value at the signal processing area. The voltage value characteristic increases if the refrigerant pressure increases, and decreases if the refrigerant pressure decreases.
am3zzn00005367
|
Fail-safe