PID/DATA MONITOR INSPECTION [i-ELOOP]
id130201000500
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
3. Select the applicable PID from the PID table.
4. Verify the PID data according to the directions on the screen.
Item |
Unit/Condition |
description |
Condition/Specification (Reference) |
|
---|---|---|---|---|
ALT_STOP_REQ
|
Off/On
|
Generator output stop request to PCM
|
• Displays the generator output stop request to the PCM.
|
|
BYPS_RLY
|
—
|
Bypass relay connection request from PCM
|
• Displays the bypass relay connection request from the PCM.
|
|
BYPS_STAT
|
Bypass Off/Bypass On/Bypass Off fault/Bypass On fault
|
Bypass relay operation status
|
• Displays the bypass relay status.
|
|
CAP_DIS_RLY
|
—
|
Capacitor interrupt relay status
|
• Displays the capacitor interrupt relay status.
|
|
CAP_V
|
V
|
Capacitor voltage
|
• Displays the capacitor voltage.
|
|
CAPA_IN_C
|
F
|
Capacitor capacitance measured value
|
• Displays the capacitor capacitance measured value.
|
|
CAPA_IN_R
|
Ω
|
Capacitor internal resistance measured value
|
• Displays the capacitor internal resistance measured value.
|
|
CAPA_TEMP
|
°C, °F
|
Capacitor temperature
|
• Displays the capacitor temperature.
|
|
CAPA_UL_V
|
V
|
Capacitor upper limit voltage
|
• Displays the capacitor upper limit voltage.
|
|
CHG_WARN
|
Off/On
|
Charge warning request to PCM
|
• Displays the charge warning request to the PCM.
|
|
CONV_OUT_V
|
V
|
Voltage reduction circuit output voltage
|
• Displays the voltage reduction circuit output voltage.
|
|
CONV_STAT
|
Ready/Power Output (Stop)/Power Output (Normal)/Power Output (Limit)/Safe Mode/Error
|
DC-DC converter (i-ELOOP) internal voltage reduction circuit operation status
|
• Displays the voltage reduction circuit operation status.
|
|
DCDC_IN_TEMP
|
°C, °F
|
DC-DC converter (i-ELOOP) internal temperature
|
• Displays the DC-DC converter (i-ELOOP) internal temperature.
|
|
DCDC_IN_V
|
V
|
DC-DC converter (i-ELOOP) input voltage
|
• Displays the DC-DC converter (i-ELOOP) input voltage.
|
|
DCDC_OUT_A
|
A
|
DC-DC converter (i-ELOOP) output current
|
• Displays the DC-DC converter (i-ELOOP) output current.
|
|
DCDC_OUT_V
|
V
|
DC-DC converter (i-ELOOP) output voltage
|
• Displays the DC-DC converter (i-ELOOP) output voltage.
|
|
DEGEN_COUNT
|
—
|
Number of degeneration transition
|
• Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter (i-ELOOP).
|
|
DEGEN_WARN
|
OK/Degeneration warning/Degeneration
|
Degeneration warning
|
• Displays the control status due to high temperature in the DC-DC converter (i-ELOOP).
|
|
DIODE_STAT
|
O.K./FAULT
|
State of diode circuit
|
• O.K.: Diode circuit status in DC-DC converter (i-ELOOP) is normal
• FAULT: Diode circuit status in DC-DC converter (i-ELOOP) is not normal
|
|
IR_REQ
|
Off/On
|
IR request to PCM
|
• Displays the IR request to the PCM.
|
|
IR_SW_STAT
|
Connect (On)/Disconnect (Off)/Fault (On)/Fault (Off)
|
i-stop relay operation status
|
• Displays the i-stop relay operation status.
|
|
ISTOP_REQ
|
Off/On
|
i-stop inhibit request to PCM
|
• Displays the i-stop inhibit request to the PCM.
|
|
MAS_WARN
|
Off/On
|
Master warning light on request to instrument cluster
|
• Displays the master warning light on request to the instrument cluster.
|
|
OUT_M_CUR1
|
A
|
DC-DC converter (i-ELOOP) output current from the previous time that ignition was switched ON
|
• Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous time that the ignition was switched ON.
|
|
OUT_M_CUR2
|
A
|
DC-DC converter (i-ELOOP) output current from the previous two times that ignition was switched ON
|
• Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous two times that the ignition was switched ON.
|
|
OUT_M_CUR3
|
A
|
DC-DC converter (i-ELOOP) output current from the previous three times that ignition was switched ON
|
• Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous three times that the ignition was switched ON.
|
|
OUT_M_CUR4
|
A
|
DC-DC converter (i-ELOOP) output current from the previous four times that ignition was switched ON
|
• Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous four times that the ignition was switched ON.
|
|
OUT_M_CUR5
|
A
|
DC-DC converter (i-ELOOP) output current from the previous five times that ignition was switched ON
|
• Displays the average value of the DC-DC converter (i-ELOOP) output current from the previous five times that the ignition was switched ON.
|
|
PRECHG_WARN
|
Off/On
|
Pre-charge warning indication request to instrument cluster
|
• Displays the pre-charge warning indication request to the instrument cluster.
|
|
PURGE_RESLT
|
Charged/Purged/Fault
|
Purge result of capacitor electrical charge after ignition is switched off
|
• Displays the purge result of the capacitor electrical charge after the ignition is switched off.
|