PURGE SOLENOID VALVE INSPECTION [MZR 1.5, MZR 1.6]


id0116ad800900


Airflow Inspection

1.  Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [MZR 1.5, MZR 1.6].)

2.  Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZR 1.5, MZR 1.6].)

3.  Remove the purge solenoid valve. (See PURGE SOLENOID VALVE REMOVAL/INSTALLATION [MZR 1.5, MZR 1.6].)

4.  Verify that the airflow is as indicated in the table.

am3zzw00012127

Measured condition

Continuity between A—B

When voltage is not applied between terminals A and B
No airflow
When voltage is applied between terminals A and B
Airflow detected

•  If not as specified in the table, inspect the purge solenoid valve. (See PURGE SOLENOID VALVE REMOVAL/INSTALLATION [MZR 1.5, MZR 1.6].)