MANIFOLD ABSOLUTE PRESSURE (MAP) SENSOR INSPECTION [MZR 2.0, MZR 2.5]
id0140e4800900
Voltage Inspection
1. Connect the M-MDS to the DLC-2.
am3zzw00011818
|
2. Switch the ignition to ON.
3. Verify that the MAP sensor output voltage (PID: MAP) is within the specification. (See ON-BOARD DIAGNOSTIC TEST [MZR 2.0, MZR 2.5].) (See PCM INSPECTION [MZR 2.0, MZR 2.5].)