NEUTRAL SWITCH INSPECTION [MZR 2.0 DISI i-stop]
id0140j1800800
Neutral Switch No.1
Continuity inspection
1. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [MZR 2.0 DISI i-stop].)
2. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZR 2.0 DISI i-stop].)
3. Disconnect the neutral switch No.1 connector. (See NEUTRAL SWITCH NO.1 REMOVAL/INSTALLATION [G66M-R (MZR 2.0 DISI i-stop)].)
4. When the shift lever is in neutral, verify that the continuity between neutral switch No.1 terminals A and B is according to the following table:
am3zzw00011874
|
Neutral Switch No.2
Continuity inspection
1. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [MZR 2.0 DISI i-stop].)
2. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZR 2.0 DISI i-stop].)
3. Disconnect the neutral switch No.2 connector. (See NEUTRAL SWITCH NO.2 REMOVAL/INSTALLATION [G66M-R (MZR 2.0 DISI i-stop)].)
4. When the shift lever is in neutral, verify that the continuity between neutral switch No.2 terminals A and B is according to the following table:
am3zzw00011875
|