ACTIVE COMMAND MODES TABLE [WATER HEATER SYSTEM]
id070228809500
Command Name (Definition) |
Operation |
Condition/Specification (Reference) |
---|---|---|
HEATER
(Heater Status)
|
Off/On
|
• Water heater unit is not operating: Off
• Water heater unit is operating: On
|
FAN
(Fan Control)
|
Off/On
|
• Blower fan is not operating: 0%
• Blower fan is operating: 0—100%
|
GLOW
(Glow plug)
|
Off/On
|
• Glow plug is not operating: Off
• Glow plug is operating: On
|
FUEL_PMP
(Fuel pump)
|
Off/On
|
• Fuel pump (water heater unit) is not operating: Off
• Fuel pump (water heater unit) is operating: On
|