NO.1 INSUFFICIENT AIR (OR NO AIR) BLOWN FROM VENTS [MANUAL AIR CONDITIONER]
id0703c2800400
1
|
Insufficient air (or no air) blown from vents
|
DESCRIPTION
|
• Problem with each vent and/or duct.
• Airflow mode does not change.
|
POSSIBLE CAUSE
|
• Malfunction in airflow mode wire
• Malfunction in VENT mode system
• Malfunction in HEAT mode system
• Malfunction in DEFROSTER mode system
• Malfunction in next vent or duct (clogging, deformation, air leakage, improper operation)
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT A/C UNIT AIRFLOW MODE SYSTEM
• Inspect the A/C unit and/or climate control unit airflow mode links, air airflow mode cranks, air airflow mode rods, and wire clamp.
• Are the above items normal?
|
Yes
|
Go to the next step.
|
No
|
Apply grease or airflow mode the links, cranks, and rods securely in their proper positions, repair or replace the airflow mode wire clamp, then go to Step 9.
|
||
2
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN VENT MODE OR OTHER MODES
• Does air blow out when in the VENT mode?
|
Yes
|
Go to Step 5.
|
No
|
Go to the next step.
|
||
3
|
INSPECT VENT
• Is the vent clogged?
|
Yes
|
Remove obstruction, then go to Step 9.
|
No
|
Go to the next step.
|
||
4
|
VERIFY THAT DUCT IN DASHBOARD IS INSTALLED
• Is the duct in the dashboard properly installed?
|
Yes
|
Inspect the duct for clogging, deformation and air leakage, then go to Step 9.
|
No
|
Install the duct securely in the proper position, then go to Step 9.
|
||
5
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN HEAT MODE OR DEFROSTER MODE
• Does air blow out when in the HEAT mode?
|
Yes
|
Go to the next step.
|
No
|
Inspect the vent for clogging, then go to Step 9.
|
||
6
|
INSPECT DEFROSTER MODE
• Does air blow out when in the DEFROSTER mode?
|
Yes
|
Operation is normal. Recheck malfunction symptoms.
|
No
|
Go to the next step.
|
||
7
|
INSPECT VENT
• Is the vent clogged?
|
Yes
|
Remove obstruction, then go to Step 9.
|
No
|
Go to the next step.
|
||
8
|
VERIFY THAT DEFROSTER DUCT IS INSTALLED
• Is the defroster duct properly installed?
|
Yes
|
Inspect the duct for clogging, deformation, and air leakage, then go to the next step.
|
No
|
Install the duct securely in proper position, then go to the next step.
|
||
9
|
CONFIRM THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
• Does air blow out?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.
|