PID/DATA MONITOR TABLE [ADVANCED KEYLESS ENTRY SYSTEM]
id0902p8027400
PID |
Unit/Operation |
Data contents |
Data read/use method |
Module control terminal |
---|---|---|---|---|
LG/T_LK_SW*1
|
Off/On
|
Request switch (liftgate) operation condition
• Off: Request switch (liftgate) is off.
• On: Request switch (liftgate) is on.
|
The request switch (liftgate) input is an input signal to the start stop unit through the LF control unit.
|
2F (LF control unit communication)
|
RQ_SW_LF
|
Off/On
|
Request switch (LF) operation condition
• Off: Request switch (LF) is off.
• On: Request switch (LF) is on.
|
The signal is input to the start stop unit through the LF control unit of the request switch (LF).
|
2F (LF control unit communication)
|
RQ_SW_RF
|
Off/On
|
Request switch (RF) operation condition
• Off: Request switch (RF) is off.
• On: Request switch (RF) is on.
|
The signal is input to the start stop unit through the LF control unit of the request switch (RF).
|
2F (LF control unit communication)
|