BATTERY DISCHARGE SUPPRESSION FUNCTION


id099000002400


Purpose of Adoption

•  To suppress battery power discharge, the electrical load operation is restricted and battery discharge is suppressed.

Service Point

•  When the room fuse is removed, the Battery discharge suppression function when all of the following conditions are met.
1.  Accumulated traveled distance is less than 20 km
2.   Number of times ignition switched from ON to off is less than 60 times
3.  Traveled distance during one ignition ON period is less than 8 km

Common Inquiry

•  Not applicable

Other

•  Battery discharge suppression function conditions
1.   When ignition is switched off, room lamp/door courtesy lamp/cargo room lamp turn off in 5 minutes.
2.   While ignition is switched to ACC (IG off), all off after 25 minutes have elapsed. However, for AT vehicles, only when in P position.
3.   When ignition is switched ON (engine off) all off after 25 minutes have elapsed. However, for AT vehicles, only when in P position.
4.   When ignition is switched ON (engine off), running lights turn off in 5 minutes.