SIMULATION TEST [ZY, Z6]
id0102c7100600
• The simulation items are shown below.
Simulation item table
×: Applicable
-: Not applicable
Item
Applicable component
Unit/condition
Test condition
PCM terminal
KOEO
KOER
ACCS
A/C relay
On/Off
×
×
1AL
ALTF
Generator field coil control duty value
0 % duty
-
×
2AN
ARPMDES
Target engine speed
RPM
×
×
-
EVAPCP
Purge solenoid valve duty value
%
×
×
2AV
FAN_DUTY
Fan control duty value
%
×
×
-
FP
Fuel pump relay
On/Off
×
×
1AC
*1
1AH
*2
FUELPW1
Fuel injector duration
%
-
×
2B, 2C, 2D, 2H
GENVDSD
Target generator voltage
V
-
×
2AN
HTR11
Front HO2S heater
On/Off
×
×
2AM
HTR12
Rear HO2S heater
On/Off
×
×
2AT
IAC
IAC valve
%
×
×
2X, 2AB
IMRC
Variable tumble control
On/Off
×
×
2AF, 2AJ
IMTV
Variable intake-air control
On/Off
×
×
2AO, 2AS
INJ_1
Fuel injector No.1
Off
-
×
2B
INJ_2
Fuel injector No.2
Off
-
×
2C
INJ_3
Fuel injector No.3
Off
-
×
2D
INJ_4
Fuel injector No.4
Off
-
×
2H
SEGRP
EGR valve
Step
×
×
2N, 2R, 2V, 2Z
test
Test mode
On/Off
×
×
-
VT ACT1
Valve timing
°
-
×
2AG, 2AK
VT DUTY1
OCV
%
×
×
2AG, 2AK
*1
:
With immobilizer system
*2
:
Without immobilizer system