• The external tester communication function enables communication of diagnostic data (DTC read-outs, input/output signal read-outs, and operation of input/output parts) between the ABS HU/CM or the DSC HU/CM and an external tester.
• Serial communication (two-way communication) allows for multiple data to be sent and received instantly along the same line.
• By connecting the WDS or equivalent to the DLC-2, diagnostic data can be sent and received between the WDS or equivalent and the ABS HU/CM or DSC HU/CM using the CAN_H and CAN_L terminals (within the DLC-2).
• The ABS HU/CM or DSC HU/CM receives the command signals of the malfunction detection function, PID/data monitor function, and the active command modes function from the WDS or equivalent, and sends DTCs and data regarding the operating condition and status of each input/output part to the WDS or equivalent.