SIMULATION FUNCTION


id050200100800

• By using the WDS or equivalent, simulation items for input/output parts preset in the PCM can be optionally selected and operated regardless of PCM control conditions.

Simulation Item Table

X: Available

Simulation item

Applicable component

Unit/Condition

Operation

PCM terminal

IG ON

Idle

ZY, Z6

LF, L3

LPS
Pressure control solenoid control signal in PCM
%
X
X
1AF, 1AV
1G, 1H
SSA/SS1
Shift solenoid A control signal in PCM
%
X
X
1AZ
1B
SSB/SS2
Shift solenoid B control signal in PCM
%
X
X
1BH
1C
SSC/SS3
Shift solenoid C control signal in PCM
%
X
X
1BD
1D
SSD/SS4
Shift solenoid D control signal in PCM
On/Off
X
X
1AJ
1E
SSE/SS5
Shift solenoid E control signal in PCM
On/Off
X
X
1AR