NO.3 AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE


id070300800600

Manual Air Conditioner

3

Amount of air blown from vents does not change.

DESCRIPTION

• Malfunction in blower system

POSSIBLE CAUSE

• Blower relay, blower motor, resistor, fan switch malfunction (Step 1)
• A/C unit malfunction (Steps 2-4)

Diagnostic procedure

STEP

INSPECTION

ACTION

1

INSPECT BLOWER SYSTEM

• Inspect the following systems and electrical parts.
- Blower relay
- Blower motor
- Resistor
- Fan switch
- Related wiring harnesses
• Are they normal?
Yes
Go to the next step.
No
Repair or replace the malfunctioning part, then go to Step 5.
2

INSPECT TO SEE WHETHER MALFUNCTION IS IN A/C UNIT OR ELSEWHERE

• Turn the ignition switch to the ON position.
• Turn the fan switch on.
• Recirculate air inside the vehicle.
• Does the blower motor rotate smoothly?
Yes
Go to Step 4.
No
Go to the next step.
3

INSPECT A/C UNIT

• Inspect blower motor.
- Is the fan free of interference from the A/C unit case?
- Is the fan free of foreign material and obstructions?
• Is the fan normal?
Yes
Go to the next step.
No
Remove obstruction, repair or replace the fan and A/C unit case, then go to Step 5.
4

INSPECT A/C UNIT INTAKE VENT

• Is the A/C unit intake vent clogged?
Yes
Remove obstruction, then go to the next step.
No
Inspect if there are any obstructions in the A/C unit passage, then go to the next step.
5

VERIFY THAT MALFUNCTION SYMPTOM OCCURS AFTER REPAIR

• Does air blow out?
Yes
Troubleshooting completed.
Explain repairs to customer.
No
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.